Troubleshooting; Errors In The Program Sequence - Fronius Robacta Reamer X-Line J Operating Instructions Manual

Welding torch cleaning
Hide thumbs Also See for Robacta Reamer X-Line J:
Table of Contents

Advertisement

Troubleshooting

Errors in the Pro-
Parting agent is not injected
gram Sequence
Parting agent container is full
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Welding torch has been poorly cleaned or is damaged
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Injection quantity too low
Extend injection time
Intake filter of the parting agent hose in the parting agent container is con-
taminated
Clean the suction filter of the parting agent hose with compressed air (for
more information, see section
from page 38)
No signal from robot
Check robot program
Parting-agent injection nozzle blocked
Clean the parting-agent injection nozzle
Notify the service team (parting-agent injection nozzle needs replacing)
Vacuum pump defective
Contact service team (vacuum pump needs replacing)
Solenoid valve has mechanical fault
Contact service team (solenoid valve needs replacing)
Position of the cleaning motor incorrectly set
Correctly set the position of the cleaning motor
Gas nozzle is clamped in incorrect position
Adjust the gas nozzle clamping device
Cleaning cutter does not fit the welding torch geometry
Fit a correct cleaning cutter
Cleaning cutter worn
Replace cleaning cutter
Starting Up the Parting Agent Atomizer
63

Advertisement

Table of Contents
loading

This manual is also suitable for:

Robacta reamer x-line j alu

Table of Contents