Before installation

Intended Use

The cleaning device is used exclusively to mechanically clean Fronius robot welding
torches in automatic mode within the limits of technical data, especially to clean the gas
nozzle and gas nozzle internal space. Any other use does not constitute proper use. The
manufacturer shall not be liable for any damage resulting from such improper use.
Proper use also means
-
-
-
Operating per-
sonnel, mainten-
ance personnel
Danger due to machines starting automatically.
This can result in severe personal injury and damage to property.

Setup regulations

The cleaning device has been tested according to protection class IP 20. This means:
-
-
The device should not be set up and operated outdoors. The installed electrical compon-
ents should be protected against direct exposure to moisture.
Danger from devices falling or toppling over.
This can result in severe personal injury and damage to property.
Specifications for
To ensure the proper functioning of the cleaning device, fulfill the following specifications
the Compressed
for the compressed air supply:
Air Supply
-
-
Reading these Operating Instructions in their entirety
Following all instructions and safety rules in these Operating Instructions
Carrying out all the specified inspection and servicing work
WARNING!
In all situations, the device must only ever be operated by one person. In addition,
make sure that there are no other people in the device's operating area while it is in
operation.
In all situations, the device must only ever be maintained by one person. In addition,
make sure that there are no other people in the device's operating area while work
on it is ongoing.
Protection against solid foreign bodies larger than Ø 12.5 mm (0.49 in.)
No protection against penetrating water
WARNING!
Always screw the cleaning device to the surface.
Set up a compressed air supply using the pressure relief valve and compressed air
filter
Guarantee the compressed air quality in accordance with ISO 8573-1:2001, class 7
4 3, instrument air
Solid particle concentration £ 10 mg/m
Pressure concentration point vapor £ + 3°C
Oil concentration £ 1 mg/m
3
3