Ericsson HL950 Administrator's Manual page 85

Multi service edge device
Hide thumbs Also See for HL950:
Table of Contents

Advertisement

The QoS service allows you to use IP Type of Service (ToS) and IEEE 802.1Q Class of Service (CoS)
tagging of IP traffic based on the application type or TCP/UDP port number. You can start or stop the
QoS daemon to enable or disable tagging.
The following example shows how to turn on tagging for all SNMP packets sent to port 161, with a
class of service set to 1, and a type of service set to 7:
HL950> set service qos:serv=snmp, port=161, tos=1, cos=7;
EXECUTED [0]
*HL950*> show service qos:serv=all;
QoS Daemon:
----------
QoS Daemon: Running
Realtime
Settings:
------------------
Circuit Emulation Service (CES)
Type of Service
Class of Service
Voice Over IP (VOIP)
Type of Service
Class of Service
Name
Port
----------------------------------------------
HTTP
80
SNMP
161
Notice the realtime QoS settings for CES and VoIP services. To change these realtime values enter:
HL950> set service qos:serv=ces ...
and specify the port, ToS, and CoS values.
Service Type values can be Static and Dynamic. Dynamic type identifies current CES or VoIP session
traffic.
Page 85 (159)
0xB8
7
0xB8
7
ToS CoS
Type
0x02 -
Static
0x01 7
Static
Multi Service Edge Device HL950