LIF E1 Module Configuration:
HL950> set interface line x1:tmode=unframed, cmode=slave;
HL950> start interface line x1
ATM VCC Configuration:
HL950> add interface atm vcc:name=dslam, type=aal1, vcc=0/40, srvtype=cbr,
pcr=2309500;
CES Application Configuration:
HL950> add ces atm:name=hl950_1, vcname=dslam, type=udt, clock=external,
jb=10;
HL950> start ces atm:name=hl950_1;
__________________________________________________________________________________
The HL950 Branch Office configuration (refer to Figure 10):
__________________________________________________________________________________
WIF 2x SHDSL Module Configuration:
HL950> set interface wan shdsl:ntrmode=local;
HL950> start interface wan shdsl
LIF E1 Module Configuration:
HL950> set interface line x1:tmode=unframed, cmode=master;
HL950> start interface line x1
ATM VCC Configuration:
HL950> add interface atm vcc:name=dslam, type=aal1, vcc=0/40, srvtype=cbr,
pcr=2309500;
CES Application Configuration:
HL950> add ces atm:name=hl950_2, vcname=dslam, type=udt, clock=adaptive,
jb=10;
HL950> start ces atm:name=hl950_2;
__________________________________________________________________________________
Verification tips:
To verify that the CES circuits are up on both sides, use the show ces atm command.
!
Use the show interface atm vcc stats command so that the PVC is established between the
!
HL950 and the DSLAM.
To verify that there are no clocking slips, use the show ces atm name=abcd command
!
and see if the under runs or overflows are increasing. Make sure to use this command on the
Branch Office side as well.