Ericsson HL950 Administrator's Manual page 34

Multi service edge device
Hide thumbs Also See for HL950:
Table of Contents

Advertisement

Multi Service Edge Device HL950
Administrator's Guide
CES Application Configuration:
HL950> add ces atm:name=hl950_1, vcname=dslam, type=udt, clock=external,
jb=21, speed=8;
HL950> start ces atm:name=hl950_1;
__________________________________________________________________________________
The HL950 Branch Office configuration (refer to Figure 12):
__________________________________________________________________________________
WIF 2x SHDSL Module Configuration:
HL950> set interface wan shdsl:ntrmode=local;
HL950> start interface wan shdsl
LIF E1 Module Configuration:
HL950> set interface line serial:cts=on, dsr=on, dcd=on, txcsrc=int,
rxcsrc=txc;
HL950> start interface line serial
ATM VCC Configuration:
HL950> add interface atm vcc:name=dslam, type=aal1, vcc=0/40, srvtype=cbr,
pcr= 578000;
CES Application Configuration:
HL950> add ces atm:name=hl950_2, vcname=dslam, type=udt, clock=adaptive,
jb=21, speed=8;
HL950> start ces atm:name=hl950_2;
__________________________________________________________________________________
Verification tips:
To verify that the CES circuits are up on both sides, use the show ces atm command.
!
Use the show interface atm vcc stats command so that the PVC is established
!
between the HL950 and the DSLAM.
To verify that there are no clocking slips, use the show ces atm name=abcd command
!
and see if the under runs or overflows are increasing. Make sure to use this command on the
Branch Office side as well.
EN/LZT 108 5995 R3
June 2003
Page 34 (159)

Advertisement

Table of Contents
loading

Table of Contents