~aa1

Applies to: All analogue input/output products
Description:
Command to reset the watchdog timeout status of the device.
Command Syntax:
Delimiter character
~
aa
Address of the device in hexadecimal format (00 to FF)
1
Command to reset the watchdog timeout status
Checksum
[CS]
(CR)
Carriage Return
Response
:
!aa[CS](CR)
Valid Command:
?aa[CS](CR)
Invalid Command:
!
Delimiter for a valid command
?
Delimiter for an invalid command
Address of the device
aa
[CS]
Checksum
Carriage Return
(CR)
Examples:
Send command to reset the watchdog status and return valid response.
~011(CR)
Command:
!01(CR)
Response: