$aa7CiRrr
Applies to: ED-549
Description:
Command to set the specified channel full scale range configuration.
Command Syntax:
Delimiter character
$
aa
Address of the device to be configured in hexadecimal format (
Command to set the channel range code
7
Command to specify the input channel where i is the input channel
Ci
Command to specify the type code where rr is the type code from the 'Range settings and
Rrr
data formats' table
[CS]
Checksum, if enabled
Carriage Return
(CR)
Response
:
!aa[CS](CR)
Valid Command:
?aa[CS](CR)
Invalid Command:
Delimiter for a valid command
!
?
Delimiter for an invalid command
aa
Address of the device which responded
Checksum
[CS]
(CR)
Carriage Return
Examples:
Send command to set the first channel to ±5V Full Scale Range.
$017C0R09(CR)
Command:
!01(CR)
Response:
Send command to set the fourth channel to ±500mV
$017C3R0B(CR)
Command:
!01(CR)
Response:
Ethernet Analogue DIO
Product Manual V1.2
$aa7CiRrr[CS](CR)
© Copyright Brainboxes Ltd
00
to FF)