$aaM0

Applies to: All analogue input/output products
Description:
Command to read the device model
Command Syntax:
Delimiter character
$
Address of the device in hexadecimal format (00 to FF)
aa
M0
Command to read the device's model
Checksum
[CS]
Carriage Return
(CR)
Response
:
!aa(Data)[CS](CR)
Valid Command:
?aa[CS](CR)
Invalid Command:
Delimiter for a valid command
!
?
Delimiter for an invalid command
Address of the responding device
aa
Model of the device
(Data)
[CS]
Checksum
Carriage Return
(CR)
Examples:
Reads the device model. Command sent to the ED-549 and a valid response is returned with the device's
model, ED-549.
$01M0(CR)
Command:
!01ED-549(CR)
Response:
Ethernet Analogue DIO
Product Manual V1.2
$aaM0[CS](CR)