(SIN?L)
Result:
(SIN!L001 000 0000 "None")
(SIN!L001 001 0001 "One-Port Dual-Input 3D L:SDI0,R:SDI1")
(SIN!L001 001 0002 "One-Port Dual-Input 3D L:SDI2,R:SDI3")
(SIN!L001 001 0003 "One-Port Dual-Input 3D L:HDMI0,R:HDMI1")
(SIN!L001 001 0004 "One-Port Dual-Input 3D L:DP0,R:DP1")
(SIN!L001 000 0005 "Christie Link [B]")
(SIN!L001 000 0006 "Christie Link [A]")
(SIN!L111 "--END--")
SNM–SNMP Configuration
Configures SNMP support for the projector.
Commands
Command
SNM+LAMP <0 | 1>
SNM+LIFE <0 | 1>
SNM+POWR <0 | 1>
SNM+READ "<name>"
SNM+SIGN <0 | 1>
SNM+STAL <0 | 1>
SNM+TIP1 "<IP address>"
SNM+TIP2 "<IP address>"
SNM+TIP3 "<IP address>"
SNM+THRM <0 | 1>
Examples
Set the SNMP read community name to public:
Christie TruLife+ Technical Reference–Serial Commands
020-103316-01 Rev. 1 (09-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
Description
Enables or disables light source
faults SNMP trap.
Enables or disables light source
life limit warnings SNMP trap.
Enables or disables power state
changes SNMP trap.
Sets the SNMP Read community
name.
Enables or disables video signal
changes SNMP trap.
Enables or disables fan/cooling
faults SNMP trap.
Sets up to three IP addresses for
traps to be sent.
Enables or disables temperature
faults SNP trap.
Serial API commands
Values
0 = Disables light source faults
1 = Enables light source faults (Default)
0 = Disables light source life limit warnings
1 = Enables light source life limits (Default)
0 = Disables power state changes
1 = Enables power state changes (Default)
name = String value, maximum 32
characters
Default name = private
0 = Disables video signal changes
1 = Enables video signal changes (Default)
0 = Disables fan/cooling faults
1 = Enables fan/cooling faults (Default)
IP address = String value
0.0.0.0 disables notifications (Default)
0 = Disables temperature faults
1 = Enables temperature faults (Default)