Examples
Get the language:
(LOC+LANG?)
Result:
(LOC+LANG!001)
Set the language to French:
(LOC+LANG 1)
Set the temperature to Fahrenheit:
(LOC+TEMP 1)
LVO–Lens Vertical Position Adjustment
Sets the lens vertical location to an absolute position.
This command is only enabled when the projector is on.
Commands
Command
Description
LVO?m
Returns the minimum and maximum range
of the vertical axis based on the last lens
calibration performed. The returned range is
persistent across AC cycles. (Read-only)
LVO <position>
Adjusts the vertical location of the lens to
the specified position. (Saved value)
Examples
Move the lens to position 500 on the vertical axis:
(LVO 500)
MSP–OSD Menu Position Presets
Sets the default menu position on the screen.
Commands
Command
Description
MSP?
Returns the current on-screen display position preset.
(Read-only)
MSP <value>
Changes the location of the on-screen display.
Christie TruLife+ Technical Reference–Serial Commands
020-103316-01 Rev. 1 (09-2020)
Copyright
©
2020 Christie Digital Systems USA, Inc. All rights reserved.
Serial API commands
Values
—
position = A numeric valuethat is subject to
the range returned in LVO?m
Values
—
0 = Top left (Default)
1 = Top center