5. Horizontal Distance Input after Angle-only Shot

Press the [O/S] key on the BMS and select [5] to
enter the Input HD function.
Turn the telescope to the direction of the point you
are to store and input the HD (usually taped distance
from the instrument point).
Input PT (and CD) and press the [ENT] key.
The target point (Tgt) is calculated and recorded to
the Job as a SS record.
= Sample records in [O/S]
SS,158,0.0000,77.0518,62.08380,108.06510,11:51:48,
CO, Input HD:76.1243
• This function is convenient when the instrument is very close to the point and is
difficult to take a measurement using the EDM.
Tgt
HD
[5.Input HD] =