5. 2-Pt Reference Plane (V-Pln)
Measuring Distance and Offset Values on the Vertical Plane
P2
3
dz
P1
baseline
Sta
Press the [6] key on the PRG menu to enter the 2-Pt
Reference Plane function.
Input two points to define the plane.
Direct measurement of the point is available by the
[MSR] softkey.
[MSR]
When you press the [MSR] softkey, a temporary
observation screen is shown.
Press the [MSR1] or [MSR2] key. After taking a
measurement, it automatically proceeds to the
Record PT screen.
Input PT and CD then press the [ENT].
Input the second point on the vertical plane and
press the [ENT] key.
3-64