4) In Angle ([ANG] key) function
5) In StakeOut
• In Stakeout, the Last ST record will NOT be resumed by the [1.Continue]. Only
when you are sure of the previous ST coordinates and that the current HA
orientation is still correct, the option [1.Continue] can be used. Otherwise,
records in this function may not turn out to be correct.
Calculating ST failed in Resection (after deleting a
point in "View shots" screen).
Action: Press any key to return to the PT input
screen. Take another shot to calculate
STN coordinate.
[ANG] → [4.F1/F2] is pressed without a F1/F2
measurement in station setup.
Action: Return to a Station setup and take F1/F2
measurement to the BS.
If no Stn Setup or BS check is done when entering
the Stakeout function.
[1:Continue] = goes to Stakeout menu
[2:Stn Setup] = jumps to STN menu
[ESC] = returns to the BMS
Style of the PT name does not match between "Fr"
and "To" fields.
(Ex. Fr=1, To=A200 etc.)
Action: Press any key to return to the Fr/To input
screen. Use same pattern in PT name.