Nikon COOLSHOT 40i - 6x21 Golf Laser Rangefinder Manual

Nikon COOLSHOT 40i - 6x21 Golf Laser Rangefinder Manual

Also See for COOLSHOT 40i:

Advertisement

Nikon COOLSHOT 40i - 6x21 Golf Laser Rangefinder Manual

Key features

  • Measurement range of actual distance: 7.5-590 meters/8-650 yards
  • High-quality 6x finder with multilayer coating
  • Larger ocular for easy viewing
  • Select from four measurement display modes, which can be easily switched. Golf mode displays the slope adjusted distance (Horizontal distance ± Height) which is useful for golf.
  • Target priority switching system, which can be chosen according to the target, is employed
  • Sustained pressing of the POWER ON/Measurement button enables continuous measurement function
  • Automatic power shut-off (after approx. 8 sec. unoperated)
  • Default to "Last Use" settings
  • Rainproof — JIS/IEC protection class 4 (IPX4) equivalent (under our testing conditions)
  • Invisible/Eyesafe EN/IEC Class 1M Laser

The Nikon Laser Rangefinder uses an invisible laser beam for measuring. It measures the time the laser beam takes to travel from the rangefinder to the target and back. Laser reflectivity and measurement results may vary according to climatic and environmental conditions, as well as the color, surface finish, size, shape and other characteristics of the target.

The following conditions facilitate measuring:

  • Cloudy weather
  • Bright-colored target
  • Large-size target
  • When laser incidence to the target surface is straight

Measurement may be inaccurate or fail in the following cases:

  • In snow, rain or fog
  • Small or slender target
  • Black or dark target
  • Target has stepped surface
  • Moving or vibrating target
  • When measuring the surface of water
  • Target measured through glass
  • When the target is glass or a mirror
  • When laser incidence to the target surface is oblique

Nomenclature/Composition

Nomenclature/Composition

  1. Monocular objective lens/ Laser emission aperture
  2. Laser detector aperture
  3. MODE button
  4. POWER ON/Measurement button
  5. 6x monocular eyepiece
  6. Eyecup/Diopter adjustment ring
  7. Diopter index
  8. Strap eyelet
  9. Battery chamber cover "Open" indication
  10. Battery chamber cover
  11. Product number label
  12. Indication

Composition

  • Body x1
  • Strap x1
  • Case x1
  • Lithium battery (CR2) x1

Internal display

Internal display

: Aim at the target you want to measure. Position the target at the center of the reticle.

: Appears while the laser is being irradiated for a measurement.
Do not look towards the objective lens side while this mark is shown.

: Now measuring

: "Failure to measure" or "Unable to measure"

* Because the internal display of this product is enlarged by the eyepiece, dust may sometimes be seen.
This will not, however, affect the measurement accuracy.

Measurement display mode

Measurement display mode

  1. Turn on the power.
  2. Press and hold the MODE button, then immediately press the POWER ON/ Measurement button.
  3. Release your finger from the POWER ON/ Measurement button within 2 seconds to switch the Measurement display mode.
  4. Repeat steps 2 and 3 to switch measurement display mode in rotation.

* If the buttons are not pressed in the correct order, switching will not take place.

Target priority mode

This Nikon Laser Rangefinder employs the First Target Priority/Distant Target Priority switching system (Factory default setting is First Target Priority mode).

  1. Turn on the power.
  2. Press and hold the MODE button, then press and hold the POWER ON/Measurement button. Continue to press and hold both buttons (for more than two seconds) until Target Priority modes are switched.
  3. Release both buttons after the mode has switched.

* If the buttons are not pressed in the correct order, switching will not take place.

[First Target Priority mode/Distant Target Priority mode]

When measuring overlapping subjects, First Target Priority mode displays the distance of the closest subject and Distant Target Priority mode displays that of the farthest subject.

Distance display units

Measurement results are displayed in yards/meters. (Factory default setting is yard.)

  1. Turn on the power.
  2. Press and hold the MODE button for more than two seconds. After the display unit has switched, release the button.

Battery

  1. Type of battery
    3V CR2 lithium battery x1
  2. Inserting/replacing battery
    1. Open the battery chamber cover
      Rotate the battery chamber cover counterclockwise and remove it. It may not open easily due to its rubber packing for water resistance.
    2. Insert the battery/Replace the old battery with a new one
      Insert a new battery correctly positioned following the indication seal inside the chamber. The [+] pole should be positioned toward the inside of the chamber. If the battery is not inserted correctly, the Nikon Laser Rangefinder will not operate. When replacing the battery, remove the old battery then insert a new one.
    3. Close the battery chamber cover
      Rotate the battery chamber cover clockwise to screw it into the body. It may not close easily due to the rubber packing for water resistance, but continue to turn it all the way until it stops. Confirm that the cover is securely closed.
  3. Battery level indicator
    * The battery condition mark in the internal display warns when the battery needs to be replaced.
Display Description
After power on, displays for 2 seconds only. Sufficient power available.
After power on, displays for 2 seconds only. Power getting low.
Prepare to replace the battery.
Displayed continuously. Low. Battery should be replaced with a new one.
Blinks. After blinking 3 times, automatically powers off. Power exhausted.
Replace the battery.
  1. Battery life

Continuous operation: Approx. 10,000 times (at approx. 20°C)
This figure may differ according to conditions, temperature, and other factors such as target shape, color, etc. Use only as a guide.

* The battery supplied with this Nikon Laser Rangefinder is for operation checking. Due to natural electrical discharge, the life of this battery will likely be shorter than that noted above.

* If water enters the battery chamber due to submersion, dry the battery chamber well, then replace the battery.

Measurement


Controls, adjustments or usage of procedures other than those specified herein may produce negative effects or damage to your health due to laser radiation.

Preparing

Install a battery in the battery chamber. (See "Battery")

Diopter adjustment

Adjust the diopter to obtain a clear internal display in the viewfinder.

First, rotate the diopter adjustment ring counterclockwise until it comes to a complete stop. Next, rotate the diopter adjustment ring back and forth until the internal display comes into focus.

Measuring

Before measuring, be sure to confirm each mode (Measurement display mode/Target priority mode/Distance display unit) setting.
* Please refer to each section on how to set each mode.

  1. Turn on the power.
    (Automatic power shut-off after approx. 8 seconds unoperated.)

    Immediately after power-on

    Standby
  2. Aim at the target.
    Position the target at the center of the target mark.
  3. Press the POWER ON/Measurement button to start measurement.
    After measurement, the result is displayed for approx. 8 seconds, then power automatically turns off.
    If you press the POWER ON/Measurement button during power-on, another measurement starts.

    Example of measured distance display

    Example of measurement failure

Continuous measurement function

Press and hold the POWER ON/Measurement button to start continuous measurement up to approx. 8 seconds. During measurement, the measured result is displayed consecutively while the laser irradiation mark is blinking.

If you release your finger from the button, continuous measurement stops.

When measuring a flagstick at a golf course, for example, set First Target Priority mode. Keep targeting the flagstick at the center of the target mark with the continuous measurement function to minimize handshake.

Specifications

Measurement system
Measurement range (actual distance) 7.5-590 meters/8-650 yards
Distance display (increment)

Actual distance (upper 4-digit): every 0.5m/yd.
Actual distance (lower 3-digit): every 1m/yd.
Horizontal distance/Slope adjusted distance (upper 4-digit):
every 0.2m/yd.

Height (lower 3-digit):
every 0.2m/yd. (shorter than 100m/yd.)
every 1m/yd. (100m/yd. and over)

Optical system
Magnification (x) 6
Effective diameter of objective lens (mm) 21
Angular field of view (real) (˚) 7.5
Eye relief (mm) 18.3
Exit pupil (mm) 3.5
Diopter adjustment ±4m-1
Others
Operating temperature (˚C/˚F) -10 — +50/14 — 122
Operating humidity (%RH) 80 or less (without dew condensation)
Power source CR2 lithium battery x 1 (DC 3V)
Automatic power shut-off (after approx. 8 sec. unoperated)
Dimensions (L x H x W) (mm/in.) 112 x 70 x 36/4.4 x 2.8 x 1.4
Weight (g/oz.) Approx. 160/5.6 (without battery)
Structure JIS/IEC protection class 4 (IPX4) equivalent (under our testing conditions)*
Electromagnetic compatibility FCC Part15 SubPartB class B, EU:EMC directive, AS/NZS, VCCI classB, CU TR 020
Environment RoHS, WEEE
Laser
Laser classification IEC60825-1: Class 1M/Laser Product FDA/21 CFR Part 1040.10:Class I Laser Product
Wavelength (nm) 905
Pulse duration (ns) 12
Output (W) 15
Beam divergence (mrad) Vertical: 1.8, Horizontal: 0.25

* Water resistance performance
This Nikon Laser Rangefinder is equivalent to JIS/IEC protection class 4 (IPX4) (under our testing conditions). This rating does not guarantee the water resistance performance of the unit or that it will be free from damage or problems under all conditions. Please observe the following when using:

  • The unit is not a sealed structure, so it should not be operated nor held in running water.
  • If any moisture is found on movable parts of the unit, stop using it and wipe it off.

Troubleshooting/Repair

If the Nikon Laser Rangefinder fails to function as expected, check the list before consulting your local dealer or the store where you purchased it.

  • If there is a problem with the product.
Problem Cause/Solution

Does not turn on

  • Press POWER ON/Measurement button (near side, top of the body)
  • Check battery insertion
  • Replace the battery with a new one

Unable to measure

Anomalous result

  • Confirm each mode setting
  • Confirm if it can measure a large target close to you (example: a building approx. 15m/yd. ahead of you)
  • Clean the lens surface if necessary
  • If you require a repair, please contact your local dealer or the store where you purchased the product.
    Do not repair or disassemble. It may result in a serious incident.
    Please note that Nikon is not responsible for any direct or indirect damage if the user attempts repair or disassembly.

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Nikon COOLSHOT 40i - 6x21 Golf Laser Rangefinder Manual

Advertisement

Need help?

Need help?

Do you have a question about the COOLSHOT 40i and is the answer not in the manual?

Questions and answers

Table of Contents