3.1.1 Init Dialog Box

The Init dialog box is used to set the items that need to be set when the emulator debugger starts up. The contents set in this
dialog box remain effective the next time you start the debugger.
(1) MCU tab
1) Specifying the MCU file and Serial No., using or not using the address match break function
REJ10J0845-0600 Rev.6.00 Aug. 20, 2009
Page 47 of 92
3. Usage (How to Use the Emulator Debugger)
Specifying the MCU file
Click the "Refer..." button.
"Select MCU File" dialog box will be displayed, so select the
desired MCU file.
- The MCU file contains the information specific to the target
MCU.
The "Select MCU File" dialog box will be displayed, so select the
MCU file for the target MCU in this dialog box.
(In the example here, the MCU for the R8C/17 group is selected.)
The specified MCU file is displayed at the MCU area field of
MCU tab.
Serial No.
Shows the currently connected emulators in list form. Select the
serial No. of the emulator you want to be connected.
Using or not using the address match break
function
With this product, the address match break function cannot be
used. Therefore be sure to deselect the check box.