Trace Window - Renesas R0E521000CPE00 User Manual

Compact emulator for r8c family
Table of Contents

Advertisement

R0E521000CPE00 User's Manual

3.5 Trace Window

The trace window is used to show the results of real-time trace measurements.
(1) Trace window
1) Opening the trace window
2) Trace window
3) Trace display mode
REJ10J0845-0600 Rev.6.00 Aug. 20, 2009
Page 62 of 92
3. Usage (How to Use the Emulator Debugger)
Trace
Clicking this button opens the trace window.
Or you can select "Trace (T)" from "Trace (T)" of "View (V)"
menu for the same effect.
Trace window
The trace window is used to show the results of real-time trace
measurements. It has the following four display modes. Mixed
mode also can be displayed.
The trace window shows the measurement result when a real-
time trace measurement has finished. The trace window
remains blank until the real-time trace measurement in progress
finishes.
Trace display mode
-
Bus mode
Bus information per cycle can be inspected. The contents are
displayed in order of execution paths.
-
Disassemble mode
The execution paths of the executed instructions can be
inspected. The contents are displayed in order of execution
paths.
-
Source mode
The execution paths of the source program can be inspected.
-
Data access mode
Data read/write cycles can be inspected. The contents are
displayed in order of execution paths.
Mixed mode also can be displayed.

Advertisement

Table of Contents
loading

Table of Contents