R0E436640CPE00 User's Manual

3.2 Starting Up the Emulator Debugger (Init Dialog Box)

(1) MCU tab
1). Specifying the MCU file
Cancel
2) Using or not using the CPU rewrite mode and trace point function
Cancel
REJ10J0918-0300 Rev.3.00 February 15, 2007
Help
Help
3. Usage (Emulator Debugger)
Specifying the MCU file
Click the "Refer..." button.
A file selection dialog box will be displayed, so select the
desired MCU file. The MCU file is stored in the directory in
which you installed the HEW.
(Example: C:\Hew4\Tools\Renesas\DebugComp\Platform\
PDTarget\H8TinyCPE\McuFiles)
- The MCU file contains the information specific to the
target MCU.
- The MCU file you have selected is displayed in the MCU
section of the MCU tab.
Serial No.
Shows the currently connected emulators in list form. Select
the serial No. of the emulator you want to be connected.
Using or not using the trace point function
The emulator has two-point events, which are shared by the
trace function and the hardware break function. Specify
whether or not to use the trace point function.
When not using the trace point function (default),
deselect the check box. In this case, the events are used
for the hardware break function.
To use the trace point function, select the check box.
In this case, the events are used for the trace point
function. The hardware break function is disabled.
Getting trace data for valid cycles or all
cycles
With this emulator you can choose to get trace data for only
valid cycles or for all cycles.
To get data for only valid cycles (default),
Select this check box. Trace data will be acquired for
only valid cycles.
To get data for all cycles
Deselect this check box. Trace data will be acquired for
all cycles
Page 41 of 102