Installation; Fastening The Control Unit; Fixing / Connecting The Control Unit For Redundant Valve (Option) - Kessel FKA Instructions For Installation, Operation And Maintenance

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 26
3

Installation

3.1

Fastening the control unit

Make sure that the control unit is disconnected from the
power supply during installation work.
Select the mounting position making sure that:
– there is a safety socket in the direct vicinity of the control units.
– The connecting cable from the backwater flap and level sensor can
be installed correctly and routed to the control unit.
– The control unit can be fastened safely and sufficiently.
Open the housing, to do this loosen the two screws <29>
(anti-clockwise) and open the housing cover.
Fit the housing at the designated place and fit all two fastening screws
(drilling template included in the scope of delivery). Make sure that the
gap  <4> between the screw heads and fastening area is approx. 3 to
4 mm
Suspend the control unit on the two fastening screws <5> and press
down lightly
L = 168 mm see drilling template (373-123)
3.2

Fixing / connecting the control unit for redundant valve (option)

When using as a redundancy control unit, establish redundancy connection.
Colours of the connection cables
white
black
blue
Installation
Redundancy unit terminals
white (none)
black
blue
34 / 148
29
Ill. [5]
4
L
5
Ill. [6]
2019/04