Installation; Fastening The Control Unit - Kessel Comfort Instructions For Installation, Operation And Maintenance

For pumpfix / ecolift
Hide thumbs Also See for Comfort:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 29
3

Installation

3.1

Fastening the control unit

Make sure that the control unit is disconnected from the power supply during installation work.
Select the mounting position making sure that:
– there is a safety socket in the direct vicinity of the control units.
– The connecting cable from the wastewater pump, backwater flap
and level sensors can be installed correctly and routed to the control
unit.
– The control unit can be fastened safely and sufficiently.
Open the housing, to do this loosen the two screws <29> (anti-
clockwise) and open the housing cover.
Fit the housing at the designated place and fit all two fastening screws
(drilling template included in the scope of delivery). Make sure that the
gap  <4> between the screw heads and fastening area is approx. 3 to
4 mm
Suspend the control unit on the two fastening screws <5> and press
down lightly
L = 254 mm see drilling template (373-123)
2019/04
29
37 / 168
Fig. [5]
4
L
5
Fig. [6]