Chapter 3 Connections and Wiring|ASDA-A&A+ Series
Signal
VCC
Power
GND
Other
The Digital Input (DI) and Digital Output (DO) have factory default settings which correspond to the
various servo drive control modes. (See section 1.5). However, both the DI's and DO's can be
programmed independently to meet the requirements of the users.
Detailed in Tables 3.B and 3.C are the DO and DI functions with their corresponding signal name and
wiring schematic. The factory default settings of the DI and DO signals are detailed in Table 3.G and
3.H.
All of the DI's and DO's and their corresponding pin numbers are factory set and non-changeable,
however, all of the assigned signals and control modes are user changeable. For Example, the factory
default setting of DO5 (pins 28/27) can be assigned to DO1 (pins 7/6) and vise versa.
The following Tables 3.B and 3.C detail the functions, applicable operational modes, signal name and
relevant wiring schematic of the default DI and DO signals.
Table 3.B DO Signals
DO
Signal
Code
SRDY
SON
3-20
Call 1(800)985-6929 for Sales
Pin No
VCC is a +12V power rail provided by the drive. It
can be used for the input on an analog speed or
20
torque command. Maximum permissible current
100mA.
12,13,
The polarity of VCC is with respect to Ground (GND).
19,44
14,29,
38,39,
See previous note for NC terminals CN1 connector
NC
40,46,
on page 3-15.
48
Pin No.
Assigned
DO
(Default)
Control
Mode
+
01
ALL
7
Not
02
-
assigned
deltaacdrives.com
Details
Details
-
SRDY is activated when the servo drive is
6
ready to run. All fault and alarm conditions, if
present, have been cleared.
SON is activated when control power is
applied the servo drive. The drive may or
may not be ready to run as a fault / alarm
condition may exist.
Servo ON (SON) is "ON" with control power
-
applied to the servo drive, there may be a
fault condition or not. The servo is not ready
to run. Servo ready (SRDY) is "ON" where
the servo is ready to run, NO fault / alarm
exists. (P2-51 should turn servo ready SRDY
off / on)
deltaacdrives.com
sales@deltaacdrives.com
Wiring Diagram
(Refer to 3.3.4)
Wiring Diagram
(*1)
(Refer to 3.3.4)
C5/C6/C7/C8
Revision April 2009