Chapter 7 Servo Parameters|ASDA-A&A+ Series
Table 7.A Input Function Definition
Setting
Sign
Value
SON
01
ARST
02
GAINUP
03
CCLR
04
ZCLAMP
05
CMDINV
06
HOLD
07
CTRG
08
TRQLM
09
SPDLM
10
7-90
Call 1(800)985-6929 for Sales
deltaacdrives.com
Servo On. Switch servo to "Servo Ready". Check parameter P2-51.
Alarm Reset. A number of Faults (Alarms) can be cleared by activating ARST.
Gain switching in speed and position mode. When GAINUP is activated (P2-27 is set
to 1), the gain is switched to the gain multiplied by fluctuation
Pulse clear (see P2-50). When CCLR is activated, the parameter P2-50 Pulse
Deviation Clear Mode is executed.
0: Clear position pulse deviation number (available in Pt and Pr mode only)
1: Clear motor feedback pulse and rotation number (available in Pt and Pr mode only)
2: Clear remaining position pulses and interrupt the motor operation (available Pr
mode only).
3: Clear remaining position pulses and interrupt the motor operation. After the motor is
stopped, activate TPOS signal (available Pr mode only).
Zero speed CLAMP. When this signal is On and the motor speed value is below the
setting value of P1-38, it is used to lock the motor in the instant position while ZCLAMP
is On.
Speed
Command
Setting value of
P1-38 (Zero speed)
ZCLAMP
input signal
Motor Speed
Setting value of
P1-38 (Zero speed)
Command input reverse control. When the drive is in Pr, Speed and Torque mode, and
CMDINV is activated, the motor is in reverse rotation.
Position command pause (Internal position control only). When the drive is in Pr mode
and HOLD is activated, the motor will pause.
Command triggered (available in Pr mode only). When the drive is in Pr mode and
CTRG is activated, the drive will command the motor to move the stored position
which correspond the POS 0, POS 1, POS 2 settings. Activation is triggered on the
rising edge of the pulse. The next internal position command will be triggered after the
DO ZSPD (At Zero speed) signal is activated (ZSPD=1).
Torque limit enabled. When the drive is in speed and position mode, and TRQLM is
activated, it indicates the torque limit command is valid. The torque limit command
source is internal parameter or analog voltage.
Speed limit enabled. When the drive is in torque mode and TRQLM is activated, it
indicates the speed limit command is valid. The speed limit command source is
internal parameter or analog voltage.
deltaacdrives.com

Digital Input Function Description