Delta Electronics ASDA-A Series User Manual page 296

Advanced ac servo drive for general purpose applications
Hide thumbs Also See for ASDA-A Series:
Table of Contents

Advertisement

Call 1(800)985-6929 for Sales
ASDA-A+ Series
Analog Monitor Output
Digital
Input/Output
Protective Functions
Communication Interface
Installation Site
Atmospheric pressure
Operating Temperature
Storage Temperature
Power System
Approvals
Footnote:
*1
Rated rotation speed: When full load, speed ratio is defined as the minimum speed (the motor will
not pause).
*2
When command is rated rotation speed, the speed fluctuation rate is defined as:
(Empty load rotation speed – Full load rotation speed) / Rated rotation speed
*3
TN system: A power distribution system having one point directly earthed, the exposed conductive
parts of the installation being connected to that points by protective earth conductor.
*4
Please refer to "Chart of load and operating time" in section 11.7 "Overload Characteristics".
Revision April 2009
Call 1(800)985-6929 for Sales
Monitor signal can set by parameters (Output voltage range: ±8V)
Servo On, Reset, Gain switching, Pulse clear, Zero speed CLAMP,
Speed/Torque limit enabled, Emergency stop, Forward / Reverse
inhibit limit, Position / Speed mode switching, Speed / Torque mode
Input
switching, Torque / Position mode switching, Feed step selection
input, Feed step mode input, Auto run input, Electronic gear ratio
(Numerator) selection
Encoder signal output (A, B, Z Line Driver / Z Open collector)
Servo ready, Servo On, At Zero speed, At Speed reached, At
Output
Positioning completed, At Torques limit, Servo alarm (Servo fault)
activated, Electromagnetic brake control, Homing completed, Output
overload warning, Servo warning activated, Internal position
command completed
Overcurrent, Overvoltage, Undervoltage, Motor overheated,
Regeneration error, Overload, Overspeed, Abnormal pulse control
command, Excessive deviation, Watch dog execution time out,
Encoder error, Adjustment error, Emergency stop activated, Reverse/
Forward limit switch error, Memory error, DSP communication error,
Serial communication error, Input power phase loss, Serial
communication time out, Command write-in error, short circuit
protection of U, V, W, and CN1, CN2, CN3 terminals
Indoor location (free from direct sunlight), no corrosive liquid and gas
(far away from oil mist, flammable gas, dust)
Altitude
o
0
C to 55
cooling will be required)
Humidity
Vibration
9.80665m/s
IP Rating
deltaacdrives.com
Chapter 11 Specifications|ASDA-A&A+ Series
4.5kW
5.5kW
45
RS-232/RS-485/RS-422
Altitude 1000m or lower above sea level
86kPa ~ 106kPa
o
C (If operating temperature is above specified range, forced
o
o
-20
C to 65
C (-4°F to 149°F)
0 to 90% (non-condensing)
2
(1G) less than 20Hz, 5.88m/ s
TN System
IEC/EN 61800-5-1, UL 508C
deltaacdrives.com
sales@deltaacdrives.com
7.5kW
55
75
2
(0.6G) 20 to 50Hz
IP20
*3
sales@deltaacdrives.com
11-5

Hide quick links:

Advertisement

Table of Contents
loading