Chapter 7 Servo Parameters|ASDA-A&A+ Series
P1 - 25
PO6H
Default: 0
Applicable Control Mode: Pr
Unit: rev
Range: -30000 ~ +30000
Settings:
This parameter is used to set rotation cycle number of internal position 6.
P1 - 26
PO6L
Default: 0
Applicable Control Mode: Pr
Unit: pulse
Range: +/-max. cnt/rev
Settings:
This parameter is used to set rotation pulse number of internal position 6.
Stroke6 = PO6H × (cnt/rev) + PO6L
P1 - 27
PO7H
Default: 0
Applicable Control Mode: Pr
Unit: rev
Range: -30000 ~ +30000
Settings:
This parameter is used to set rotation cycle number of internal position 7.
P1 - 28
PO7L
Default: 0
Applicable Control Mode: Pr
Unit: pulse
Range: +/-max. cnt/rev
Settings:
This parameter is used to set rotation pulse number of internal position 7.
Stroke7 = PO7H × (cnt/rev) + PO7L
7-36
Call 1(800)985-6929 for Sales
deltaacdrives.com
6th Position Command for Rotation
6th Position Command for Pulse
7th Position Command for Rotation
7th Position Command for Pulse
deltaacdrives.com
sales@deltaacdrives.com
Communication Addr.: 0119H
Related Section:
Section 6.2.2
Communication Addr.: 011AH
Related Section:
Section 6.2.2
Communication Addr.: 011BH
Related Section:
Section 6.2.2
Communication Addr.: 011CH
Related Section:
Section 6.2.2