Universal Robots UR10/CB3 User Manual page 48

Hide thumbs Also See for UR10/CB3:
Table of Contents

Advertisement

Remote ON/OFF control
Remote ON/OFF control can be used to turn the control box on and off without using the teach
pendant. It is typically used in the following applications:
• When the teach pendant is inaccessible.
• When a PLC system must have full control.
• When several robots must be turned on or off at the same time.
The remote ON/OFF control provides a small auxiliary 12V supply, which is kept active when the
controller box is turned off. The "on" and "off" inputs are intended for short time activation only.
The "on" input works in the same way as the power button. Always use the "off" input for remote
"off" control as this signal allows the control box to save open files and shut down correctly.
The electrical specifications are shown below.
Terminals
[12V - GND]
[12V - GND]
[ON / OFF]
[ON / OFF]
[ON / OFF]
[ON]
The following examples show how to use remote ON/OFF.
NOTE
A special feature in the software can be used to load and start programs
automatically, see
UR10
Analog
AG
AI0
AG
AI1
AG
AO0
AG
AO1
Power
PWR
GND
24V
0V
Parameter
Voltage
Current
Inactive voltage
Active voltage
Input current
Activation time
part Part II PolyScope Manual on
40
Min
Typ
Max
10
12
13
-
-
100
0
-
0.5
5
-
12
-
1
-
200
-
600
page 85.
Unit
V
mA
V
V
mA
ms
User Manual

Advertisement

Table of Contents
loading

Table of Contents