Factory Settings "R-Tronic" And "Aktor Mh/Md Con B; Reset (Only "R-Tronic") - oventrop R-Tronic RT B Installation And Operating Instructions Manual

Climate display device/control
Table of Contents

Advertisement

Operation

5.4.9 Factory settings "R-Tronic" and "Aktor MH/MD CON B"

It might be useful to restore the factory settings of the "R-Tronic" and the actuator if,
for instance, wrong settings that do not guarantee an efficient heat control of your room
were stored by mistake. All individual settings and the assignment of the "teached in"
actuators will be cancelled when restoring the factory settings. This is why the radio
communication between the "R-Tronic" and the actuator(s) always has to be restored
(see chapter 4.6).
1. You are in the submenu SETTINGS. Confirm the selection by pressing the menu-
button. INSTALLATION will be displayed as before.
2. Turn the menu-button to the right and confirm the selection FACTORY
SETTINGS as well as the following selection RESTORE. If you are sure that the
"R-Tronic" factory settings shall be restored, turn the menu-button to the right and
confirm the selection YES.
► The factory settings are restored now. The date and time have to be set again
and any other settings must be repeated.
NOTE
The factory settings of the actuator must always be restored, too.
The factory settings of the actuator are restored as follows:
1. Remove the casing cover of the actuator by pushing down both release tabs and
by removing the cover at the same time.
2. Disconnect the actuator from the power supply for a few seconds by removing
one of the batteries from the battery case.
3. Reinsert the battery and keep the "teach in"/adjustment button pressed at the
same time. Both LEDs will flash alternately green and red twice.
The existing communication data of the "R-Tronic" is cancelled now. The push
rod of the actuator will retract after a successful reset (see illustr. 11) (removal
position) – this is confirmed by five flashes of both LEDs.

5.4.10 Reset (only "R-Tronic")

A restart can be carried out during a reset (e.g. in case of a malfunction). Contrary to
the reset to factory settings, all existing settings except for the date and time will be
maintained. This function is selected in the menu SETTINGS ► RESET ► START
RESET.
- 48 von 64 -