INSTALLATION INSTRUCTIONS

These installation instructions are intended for qualified
equipment installers:
PLACEMENT
Carefully uncrate the machine. Take caution not to
damage components which may be mounted on the top or
sides of the machine.
Set the unit in place and adjust the feet to level the
machine.
CHEMICALS
Upon completed installation of the dishwasher, contact a
local detergent/chemical supplier for the correct chemicals
for your machine.
Electrical connection points for the detergent dispenser and
rinse injector are located inside the control panel. Refer to
the machine wiring diagram for the proper connection points.
Dispensers may be connected to the 24VAC terminal block
provided. refer to the schematic for exact labeling.
The detergent density probe should be placed in the hole
provided.
WARNING:
DISCONNECT ELECTRICAL POWER SUPPLIES & TAG
OUT IN ACCORDANCE WITH APPROPRIATE CODES AT
THE DISCONNECT SWITCH TO INDICATE THE CIRCUIT
ELECTRICAL CONNECTIONS
Connect electrical lines sized for the correct voltage,
current and phase of the machine. These should agree
with the machine requirements indicated on the
nameplate and labels on the control panel.
Machines not provided with a single-point connection
require two separate electrical connections for:
1. pumps and control circuit
2. wash tank heater(s)
If an electrical booster is provided, connect the booster
directly to power source.
CAUTION:
Connections must be made to a circuit breaker or fused
disconnect as provided by the end-user and required by
local codes. A laminated wiring diagram is inside the
control panel.
CX20 SERIES
IS BEING SERVICED.
PART 2 INSTALLATION INSTRUCTIONS
As with any 3 phase system, an electrician must
check all motors for proper phasing, i.e., Pump
motors must be running in direction indicated by
arrow on housing.
MECHANICAL CONNECTIONS
All lines must be flushed prior to use to remove debris.
Connect a 110 F (for 70 F rise) or a 140 F (for 40 F rise)
water line for tank fills and booster as tagged and noted on
the installation drawings.
If machine is provided with steam heat connect the steam
lines and steam condensate lines as tagged and noted on
installation drawings.
Connect the drain lines. Drain lines must be as specified on
installation drawings.
If a booster is provided, a 110 F (for 70 F rise) or a 140 F
(for 40 F rise) water connection is necessary. A steam
booster also requires a condensate line.
Drain lines must be as specified on installation
drawings. Drain line should be properly vented and
should have fall of not less than 1/4" to the foot of
Some area plumbing codes require drains to flow
into an open gap with an opening twice the diameter
of the pipe. Check with your local plumbing codes
for the type of drain connection required.
Do not reduce the size of lines as specified in
installation drawings. All lines are sized to facilitate
necessary flows, pressures, etc.