INSTALLATION INSTRUCTIONS

Commander 18-5 Series & CS Series
Placement
Carefully uncrate machine. Take caution not to
damage components which may be mounted on
the top or sides of the machine. Set unit in place
and adjust the feet to level the machine.
Fasten the tables to the load and unload side of the
machine. Most installations require fastening the
turn-down lip of the dish tables to the side of the
machine with flathead countersunk screws. The
table design should provide horizontal clearance of
30" for servicing.

Electrical Connections

Connect electrical lines sized for the correct
voltage, current and phase of the machine. These
should agree with the machine requirements
indicated on the nameplate and labels on the con-
trol panel.
208VAC/3È
Model
18-5(C)
steam heat
18-5(C)
electric heat
18-5(C)
electric heat
Insinger SCB
18-5H
steam heat
18-5H
electric heat
18-5H
electric heat
Insinger SCB
Door Type Series DOC COM 1.0 06
Fuse Sizing Chart
230VAC/3È
6A
6A
15A
15A
60A
50A
15A
10A
25A
25A
70A
60A
PART 2 INSTALLATION INSTRUCTIONS
A single-point electrical connection is provided for
the pumps, control circuit, and wash tank heater.
If an electric booster is provided, connect power
directly to the booster.
If the Insinger Self-Contained booster is provided
the machine comes standard with a Single-Point
Connection (to include the booster).
Connections must be made to a circuit breaker
or fused disconnect as provided by the
end-user and required by local codes.
A laminated wiring diagram is inside the control panel.
380VAC/3È
460VAC/3È
6A
10A
35A
6A
15A
40A
9
www.insingermachine.com 800-344-4802
CAUTION:
220VAC/1È
6A
15A
10A
30A
25A
100A
6A
25A
15A
45A
30A
110A