Download Print this page

Installation Instructions; Electrical Connections - Insinger Commander 18-6 Installation, Operation And Maintenance Instructions

Door type dishwashing machine
Hide thumbs Also See for Commander 18-6:

Advertisement

INSTALLATION INSTRUCTIONS

Commander 18-6 Series & CS Series
Placement
Carefully uncrate machine. Take caution not to damage
components which may be mounted on the top or
sides of the machine. Set unit in place and adjust the
feet to level the machine.
Fasten the tables to the load and unload side of the
machine. Most installations require fastening the
turn-down lip of the dish tables to the side of the
machine with fl athead countersunk screws. The table
design should provide horizontal clearance of 30" for
servicing.

Electrical Connections

Connect electrical lines sized for the correct voltage,
current and phase of the machine. These should
agree with the machine requirements indicated on the
nameplate and labels on the control panel.
Model
208VAC/3PH
18-6 (C)
Steam heat
18-6 (C)
Electric heat
18-6 (C)
Electric heat
Insinger SCB
18-6H (C)
Steam heat
18-6H (C)
Electric heat
18-6H (C)
Electric heat
Insinger SCB
DoorTypeTM2009
®
Fuse Sizing Chart
240VAC/3PH
10A
10A
20A
20A
60A
50A
10A
10A
25A
25A
60A
60A
PART 2 INSTALLATION INSTRUCTIONS
A single-point electrical connection is provided for the
pumps, control circuit, and wash tank heater.
If an electric booster is provided, connect power
directly to the booster.
If the Insinger Self-Contained booster is provided
the machine comes standard with a Single-Point
Connection (to include the booster).
CAUTION:
Connections must be made to a circuit breaker
or fused disconnect as provided by the end-user
and required by local codes.
A laminated wiring diagram is inside the control panel.
380VAC/3PH
480VAC/3PH
6A
10A
30A
10A
15A
35A
9
www.insingermachine.com
220VAC/1PH
6A
15A
10A
35A
25A
90A
6A
20A
15A
40A
30A
100A
800-344-4802

Advertisement

loading

This manual is also suitable for:

Commander 18-6cCommander 18-6hCommander 18-6hc