Insinger CX20 Series Technical Manual page 27

Table of Contents

Advertisement

2
7
8
CHEMICAL & EXTERNAL FAN BLOCKS
1
4
CHEMICAL & EXTERNAL FAN BLOCKS
(VENTLESS OPTION)
CX20 SERIES
6
5
9A / 9B
4
1
FAN SIGNAL-24VAC
(2 Amp Max)
DETERGENT PUMP SIGNAL-24 VAC
(2 Amp Max)
RINSE AID PUMP SIGNAL-24VAC
(2 Amp Max)
NEUTRAL
2
3
FAN SIGNAL-24VAC
(2 Amp Max)
DETERGENT PUMP SIGNAL-24 VAC
(2 Amp Max)
RINSE AID PUMP SIGNAL-24VAC
(2 Amp Max)
NEUTRAL
CONNECTIONS FOR
VENTLESS OPTION
(SEE SCHEMATIC)
PART 7
CONTROL BOARD FUSE BLOCKS & FUSES
ITEM
PART NUMBER
3
1
5940-01129
2
5940-01128
3
5940-01125
4
5940-01127
5
5940-01126
6
5940-01123
7
5940-01124
F3-F13
8
5920-01130
F2
9A
5920-02142
F2
9B
5920-02143
2
ITEM
1
2
3
4
27
REPLACEMENT PARTS
PARTS LIST
DESCRIPTION
Bridge, Plug In 2-Pole RED
End Bracket, Din Rail
Terminal Block
End Cover, Terminal Block
End Cover, Terminal Fuse Block
Terminal Block, Spring 2-PT Disconnect / Fuse
Terminal, Fuse Carrier w/Light (5x20mm Fuse)
Fuse, 5 x 20mm 2.0 Amp Fast Acting
Fuse, 5 x 20mm 1.0 Amp Slow-Blow (For 208-240V)
Fuse, 5 x 20mm 0.5 Amp Slow-Blow (For 440-480V)
PARTS LIST
PART NUMBER
DESCRIPTION
5940-01125
Terminal Block
5940-01128
End Bracket, Din Rail
5940-01129
Bridge, Plug In 2-Pole RED
5940-01127
End Cover, Terminal Block
www.insingermachine.com 800-344-4802
QTY
3
2
4
1
8
8
8
8
1
1
QTY
5
2
1
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cx20 hCx20 sCx20 hs

Table of Contents