First-start response
The IP addressing after a first start depends on whether a static IP addressing is al-
ready stored on the EIM card from a previous configuration. A static IP addressing
(IP address, subnet mask, gateway) entered manually is stored on the EIM card and
remains available after a first start. This means that the communication server re-
mains accessible via Ethernet interface in the same way as before the first start.
If no IP addressing is entered on the EIM card (e.g. after initial delivery), the commu-
nication server is started with DHCP after a first start. The communication server
tries to log on with the DHCP server and to enter its host name on the DNS server. If
logon is successful the communication server is accessible via the host name. If the
logon to the DHCP server fails, the communication server deactivates DHCP tem-
porarily and can be accessed via the static default value address. The communica-
tion server is then accessible with a direct connection via the IP address.
Note:
DHCP is deactivated only temporarily and is reactivated after a subse-
quent restart.
Cable types
The Ethernet switch on the communications server features Auto MDI/MDIX. With
the automatic detection straight or crossover LAN cables can be used for all con-
nection types.
Configuration
On theAMS Configuration Manager the Ethernet interfaces routed to the front
panel can be configured individually. The following settings are possible:
Tab. 75
Configuration possibilities for Ethernet interfaces
Parameter
Speed/mode
MDI
Aastra 470 ab R3.0
syd-0337/1.5 – R3.0 – 05.2013
Parameter value
<Automatic, 1G/Full-duplex, 100M/Full-duplex, 100M/Half-duplex,
10M/Full-duplex, 10M/Half-duplex>
<Auto
MDI/MDIX,
MDI
(straight),
Installation
MDIX
(crossed)>
167

Hide quick links:

Advertisement

Table of Contents
loading