Expansion Stages and System Capacity
3. 2. 3

Ethernet concept

Aastra 470 provides three GBit Ethernet interfaces, which are routed to the front
panel of the call manager card. They are used to connect to the customer's data
network (LAN) and e.g. the IP connection with an SIP provider. The socket marked
"WAN" currently has no function and remains covered.
Likewise the Ethernet interface on the front panel of the applications card is not
used as the applications server is accessed via the WebAdmin configuration tool.
As the following schematic diagram shows, all the cards are internally connected
with one another via Ethernet.
Front panel
WAN 1.1
LAN 1.2
LAN 1.3
LAN 1.4
Front panel
LAN
Application card CPU2
IP media module
IP media module
2PRI card (example)
Interface cards
Fig. 11
Overview of the Aastra 470 Ethernet concept
48
Processor
LAN
Switch
Call Manager card CPU1
1000BT
MII
GMII
Switch 1Gbit/s
1000BT
MII
GMII
1000BT
1000BT
1000BT
1000BT
100BT
100B T
Switch 100Mbit/s
100BT
100BT
100BT
100BT
100BT
100BT
100BT
100BT
Processor
IP media module
Backplane
Aastra 470 ab R3.0