6. 6. 3
Other aids
6. 6. 3. 1
Maintenance menu on the Office 45
The System Assistant function on the Office 45 under the
can be used to retrieve system information which in the event of a malfunction
provides important clues as to the cause of the fault:
Tab. 113 Maintenance menu selection:
1:
View
2:
Print
You can select from the following menu items:
1. System status
2. System failures
3. Mains voltage failures
4. Event messages
System status menu item
Tab. 114 Display of the system status lines
==
SYSTEM STATUS
BCS: 00000
SUBS: 0011
DIST: 0001
Back with [<-- |]
The system status lines provide useful information for a more in-depth fault diag-
nosis. They can be printed out and sent to customer support on request.
Tab. 115 The displayed data and what it means
Display
Description
BCS: xxxxx
Number of existing BCS references
CC: xxxxx
Number of existing call controls
SUBS: xxxx
Number of users in the system
NSUB: xxxx
Number of PISN users in the system
LINE: xxxx
Number of lines in the system
Aastra 470 ab R3.0
syd-0337/1.5 – R3.0 – 05.2013
3:
Delete
4:
Both
CC: 00000
NSUB: 0000
DDIN: 0000
Normal value /
idle state
BCS: 00000
CC: 00000
SUBS: 0000
NSUB: 0000
LINE: 0000
Operation and Maintenance
Maintenance
LINE: 0001
ABB: 1000
Note
Each active connection needs 2
BCS references
For each BCS reference there is
one or more CC
0000: No ports busy
0000: No PISN user in the system
0000: No lines defined
menu item
275