Dimensions Of Cards And Modules - Aastra 470 System Manual

Hide thumbs Also See for 470:
Table of Contents

Advertisement

Tab. 126 Electrical data
Class of protection
Input voltage
Input current
Resistant to voltage breaks
Power input with min. configuration
Power input with max. configuration
Undervoltage limit
(system reset, data backup)
Tab. 127 Heat dissipation
Basic system with auxiliary power supply unit
Maximally configured system
7. 3. 4

Dimensions of cards and modules

Tab. 128 Dimensions of cards and fan-out panels
Card
Interface cards
Call Manager card CPU1
Application card CPU2
Fan-out panel FOP
Tab. 129 Modules
Card
DSP module
IP Media module
Call charge module
Aastra 470 ab R3.0
syd-0337/1.5 – R3.0 – 05.2013
Internal power supply Aastra
470
1
103 V...127 V or 207 V...253 V,
48...62 Hz
approx. 0.2 A...2.2 A (115 V)
approx. 0.1 A...1.1 A (230 V)
< 20ms
approx. 25 W
approx. 140 W
< 90 V
Aastra 470
approx. 140 W = 504 kJ/h
approx. 400 W = 1440 kJ/h
Dimensions width x height x depth [mm]
93 x 41 x 265
154 x 41 x 265
154 x 41 x 265
481 x 44 x 69
Dimensions length x width [mm]
90 x 56
85 x 85
83 x 60
Annex
Auxiliary power supply unit
(APS2)
1
100 V...240 V, 48...62 Hz
approx. 0.2 A...4.0 A (115 V)
approx. 0.2 A...2.0 A (230 V)
< 20ms
approx. 25 W
approx. 260 W
< 90 V
283