Keithley 6482 Reference Manual page 254

Dual-channel picoammeter / voltage source
Table of Contents

Advertisement

Model 6482 Dual-Channel Picoammeter / Voltage Source Reference Manual
DIRection <name>
Parameters
Query
Description
INPut <event list>
Parameters
NOTE
Query
Description
NOTE
ILINe <NRf>
Parameters
Query
6482-901-01 Rev. A / August 2012
:ARM[:SEQuence[1]][LAYer[1]][:TCONfigure]:DIRection <name>Control arm
bypass
:TRIGger[:SEQuence[1]][:TCONfigure]:DIRection <name>Control trigger bypass
<name> = SOURce
ACCeptor
:DIRection?
This command is used to enable (SOURce) or disable (ACCeptor) control source
bypass. When enabled, operation will loop around the control source on the first
pass in the layer. After that, repeat passes in the layer are held up and will wait for
the programmed control source event.
:TRIGger[:SEQuence[1]][:TCONfigure][:ASYNchronous]:INPut <event list>Enable
event detectors
<event list> =SOURceEnable Source Event Detector
DELayEnable Delay Event Detector
SENSeEnable Measure Event Detector
NONE
Each event in the list must be separated by a comma (i.e. trigger:input source, delay,
sense).
:INPut?
When TLINk is the selected Trigger Layer control source, and an event detector in
the Trigger Layer is enabled, operation will hold up at that detector until an input
trigger is received using the trigger link. When the event detector is disabled,
operation will not hold up. It continues and performs the appropriate action.
A Trigger Layer event detector is enabled by including the parameter name in the
event list for the INPut command. For example, to enable the Source Event
Detector and Measure Event Detector, send the following command:
:TRIGger:INPut SOURce, SENSe
The Delay Event Detector will be disabled since the DELay parameter is not
included in the above event list.
To disable all the Trigger Layer event detectors, the NONE parameter must be sent alone
(i.e. trigger:input none). If it is listed with any of the other parameters, NONE will be
ignored.
:ARM[:SEQuence[1]][LAYer[1]][:TCONfigure]:ILINe <NRf>Select input line; arm
layer
:TRIGger[:SEQuence[1]][:TCONfigure]:ILINe <NRf>Select input line; trigger layer
<NRf> =
1
2
3
4
5
6
:ILINe?
Return to
Enable control source bypass
Disable control source bypass
Query state of bypass
Disable all event detectors in Trigger Layer
Query enabled event detectors in Trigger Layer
Line #1
Line #2
Line #3
Line #4
Line #5
Line #6
Query input trigger line
Section Topics
Section 16: SCPI Command Reference
16-61

Advertisement

Table of Contents
loading

This manual is also suitable for:

6482 e

Table of Contents