6.4 Bearing maintenance
•
Check that the foundation and the hold-down bolts are tight.
•
Check the packing if the pump has been left idle, and replace as required.
•
Change the oil every three months (2000 operating hours) at minimum.
•
Check the shaft alignment, and realign as required.
Annual inspections
Perform these inspections one time each year:
•
Check the pump capacity.
•
Check the pump pressure.
•
Check the pump power.
If the pump performance does not satisfy your process requirements, and the process requirements
have not changed, then perform these steps:
1.
Disassemble the pump.
2.
Inspect it.
3.
Replace worn parts.
6.4 Bearing maintenance
These bearing lubrication sections list different temperatures of pumped fluid. If your pump is ATEX
certified and the pumped fluid exceeds the permitted temperature values, then consult your ITT repre-
sentative.
Bearing lubrication schedule
Type of bearing
Oil-lubricated bearings
Grease-lubricated bear-
ings
Oil change schedule
Oil must be changed at least once a year.
Bearing temperature
Up to 60°C | 140°F
60°C to 80°C | 140°F to 176°F After 300 hours of operation Every 4000 hours of operation
80°C to 100°C | 176°F to 212°F After 200 hours of operation Every 3000 hours of operation
NOTICE:
•
Strictly maintain the oil changing schedule if the pump is operating in an potentially explo-
sive environment.
•
Change the oil every two years if the pump is left idle.
•
Dispose of used oil in accordance with local environmental regulations.
64
First lubrication
Add oil before you install and start the
pump.
Change the oil after 200-300 hours of oper-
ation, depending on bearing temperature.
N/A
First oil change
After 300 hours of operation Every 8760 hours of operation
Model ICO i-FRAME, ICOH i-FRAME Installation, Operation, and Maintenance Manual
Lubrication intervals
See the Oil change schedule table.
Every 4000 hours of operation or once a year,
whichever comes first
Every two years if the pump is left idle
Subsequent oil changes