Full Status Monitor; Bandwidth/Gain/Detection Mode Monitor; Address 15 Receiver Parameters; Command Parameters To Address 4 Receiver - Watkins-Johnson Company WJ-8718-19/FE Instruction Manual

Hf receiver
Table of Contents

Advertisement

-50
Table 2-16.
Full Status Monitor
Byte Number
Binary Code
1
1 1 0 0 1 1 1 1
Controller to Receiver
2
1 1 1 0 0 x x x
3
1 1 0 0 1 1 1 1
4
x x x x O O O l
5
0 0 1 0 0 0 1 1
6
0 1 0 0 0
1 0 1
Receiver to Controller
7
0 1 1 0 0 1 1 1
8
0 10 0 0 0 0 0
9
0 0 1 1 0 0 0 0
10
0 x 1 1 1 1 1 1
Table 2-17.
Bandwidth/Gain Mode/Detection Mode Monitor
Byte Nu
mber
Binary Code
1
2
3
4
1 1 0 0 1 1 1 1
1 1 1 0 1 1 0 0
1 1 0 0 1 1 1 1
0 1 0 0 0 0 0 0
Controller to Receiver
Receiver to Controller
Table 2-18.
Address 15 Receiver Parameters
Tuned Frequency
12.34567 MHz
BFO Frequency
-3.0 kHz
Operating Mode
Local
Bandwidth
3.2 kHz
Gain Mode
Fast AGC
Detection Mode
AM
Signal Strength
Maximum
Table 2-19.
Command Parameters to Address 4 Receiver
Tuned Frequency
23.45678 MHz
BFO Frequency
+6.0 kHz
Operating Mode
Remote
Bandwidth
50 kHz
Gain Mode
Manual
Detection Mode
CW
RF Gain
Maximum