Watkins-Johnson Company WJ-8718-19/FE Instruction Manual page 157

Hf receiver
Table of Contents

Advertisement

MAINTENANCE
WJ-8718-19/FE HF RECEIVER
4.3.2
TEST EQUIPMENT REQUIRED
Table 4-2 lists the test equipment required for corrective maintenance of
the WJ-8718-19/FE HF Receiver.
Equivalent equipment may be used.
Table 4-2.
Test Equipment Required
Instrument
Required
Recommended
Type
Characteristics
Instrument
Signal Generator
AM, FM, CW, RF output,
HP8640B
from -111 dBm to 0 dBm
Oscilloscope
dc to 50 MHz
HP180C
RF Voltmeter
1 mV to 3.0 V; -50 dBm
Boonton 92B
to +20 dBm
Digital Counter
0 to 500 MHz
HP5303A
AC Voltmeter
1 mV to 300 V, full scale
HP-400E
Digital Voltmeter
dc ranges; 196 or better
Fluke 8100A
Dummy load, 600 ohm
1/2-W dissipation
Two 1200 ohm, 1/4-W or
1/2-w resistors in
parallel
Headphones
Stereo, 600 ohm impedance,
Telex 325-02 or
or Mono
Telex 820-4
Sweep Generator
100 kHz to 11.0 MHz
HP8601A
4.3.3
RECEIVER CHECKOUT PROCEDURE GUIDELINES
Observe the following guidelines to perform the receiver checkout
procedure:
r
4-4
1.
With the receiver deenergized, connect the test
equipment as shown in Figure 4-1. Remove receiver top
and bottom covers.

Advertisement

Table of Contents
loading

Table of Contents