Example 18:
Establish Sector B scan between 3.5 MHz and 3.9 MHz in 10 kHz
steps.
[3]
[.]
[5]
[MHz]
(1)
Receiver tuned to 3.50000 MHz.
[1]
[9]
[STO]
(2)
3.50000 MHz (fl) stored in channel
19; "19" displayed in MEM ADRS
display window.
[3]
M
[9]
(3)
Receiver tuned to 3.90000 MHz.
[2]
[0]
[STO]
(4)
3.90000 MHz (f2) stored in channel
20; "20" displayed in MEM ADRS
display window.
[1]
[0]
[KHz]
(5)
Receiver tuned to 10 kHz.
[2]
[1]
[STO]
(6)
10.00 kHz (step size) stored in
channel 21; "21" displayed in MEM
ADRS display window.
2.4.6.2
Sector Lockout
When a single sector scan is desired, the undesired sector must be locked
out. The following procedure locks out a sector to establish a single sector scann
Example 19 shows a typical sector lockout command.
o
Sector Lockout - Procedure
1)
Enter designated sector channel number on keypad (17
or 18 to lockout Sector A, 19 or 20 to lockout Sector
B).
2)
Terminate command by pressing LOCK OUT termination
switch.
Example 19:
Lockout Sector B (establish single sector scan of Sector A).
Cl] £9]
(1)
Data entry; "19" displayed in
FREQUENCY/MHZ display window.
[LOCKOUT]
(2) Termination command! channels 19
and
20 will
display a lockout
attribute when accessed! Sector B
locked out.
2-28