Hf receiver
Table of Contents

Advertisement

»»«J—O I 1 0 - 1 5 / V U
111'
U L U L U l J n
INSTALLATION AND OPERATION
Sector A Frequency Data Entry - Procedure
1)
Tune receiver to desired f.
1
2)
Store fj data in channel 17 by entering "17" on keypad
and pressing STO termination switch.
3)
Tune receiver to desired f„
4)
Store f2 data in channel 18 by entering "18" on keypad
and pressing STORE termination switch.
Example 17:
Establish a Sector A scan between 5 MHz and 10 MHz
[5]
[MHz]
(1) Receiver tuned to 5.00000 MHz
[17] [STO]
(2) 5.00000 MHz (fl) stored in channel
17; "17" displayed in MEM ADRS
display window.
[1] [0] [MHz]
(3) Receiver tuned to 10.00000 MHz.
[1] [8] [STO]
(4) 10.00000 MHz (f2) stored in
channel 18; "18" displayed in MEM
ADRS display window.
o
Sector B Frequency Data Entry - Procedure
1)
Tune receiver to desired f.
2)
3)
Tune receiver to desired f
Store fx data in channel 19 by entering "19" on keypad
and pressing STO termination switch.
2'
4)
Store fg data in cnannei 20 by entering "20" on keypad
and pressing STO termination switch.
5)
Tune receiver to desired scan step size.
6)
Store step size data in channel 21 by entering "21" on
keypad and pressing STO termination switch.
2-27