INSTALLATION AND OPERATION
WJ-8718-19oFE HF RECEIVER
Table 2-9 lists the RS-232 connection -pin numbers with the respective
interchange signals and functions.
The connection between receivers will be pin for
pin compatible if each receiver is connected as shown in Figure 2-4. If one receiver
is configured as a master and the remainder are slaves, it is necessary to use reverse
cable (modem bypass).
r
2-42
Table 2-9. RS-232 Connector Pin Assignments
Pin Number
A
B
C
D
E
F
G
H
J
K
Signal
P-GND
TxD
RxD
RTS
CTS
DSR
S-GND
SYNC - TxC
SYNC -
RxC
DTR
Description
Protective Ground
.Transmitted Data
Received Data
Request To Send
Clear To Send
Data Set Ready
Signal Ground
Transmit Timing Signal
Receive Timing Signal
Data Terminal Ready