Threshold Level - Watkins-Johnson Company WJ-8718-19/FE Instruction Manual

Hf receiver
Table of Contents

Advertisement

VVJ-8718-19/FE HF RECEIVER
INSTALLATION AND OPERATION
2.4.5.3
Threshold Level
During all MFP scan operations, the recei-ved signal strength is compared to
a selected threshold level.
The threshold levels are entered as single digit codes
which are stored, along with the receiver parameters, in the memory channels.
Table
2-2 lists the single digit threshold level codes and their corresponding signal strength
levels in dBm.
Table 2-2.
Threshold Data Codes
Keypad Entry
Threshold
Cod«
a
Level
0
*See Note 1
1
-110 dBm
2
-100 dBm
3
-90 *dBm
4
-80 dBm
5
-70 dBm
6
-60 dBm
7
-50 dBm
8
-30 dBm
9
*See Note 2
* NOTE:
1.
An entered threshold data code of 0 causes the
SCAN to stop, regardless of signal strength, at the
channel where the 0 is stored.
2.
An entered threshold data code of 9 causes the
SCAN to continue regardless of signal strength.
The following procedure loads threshold data, along with the present
receiver operating parameters, into a memory channel.
Example 10 shows a typical
threshold command.
o
Threshold Entry - Procedure
1)
Enter desired threshold code on keypad.
2)
Terminate threshold command by pressing THRS
termination switch.
3)
Enter designated channel number on keypad.
4)
Terminate command by pressing STORE termination
switch.
2-21