Non-Multiplexed Bus Ac Characteristics - Dallas Semiconductor DS21354L Manual

E1 single chip transceivers;
Table of Contents

Advertisement

21.2 Non-Multiplexed Bus AC Characteristics

AC CHARACTERISTICS – NON-MULTIPLEXED PARALLEL PORT (MUX = 0)
[See Figure 21-4 to Figure 21-7]
PARAMETER
Set Up Time for A0 to A7, Valid to
CS* Active
Set Up Time for CS* Active to
either RD*, WR*, or DS* Active
Delay Time from either RD* or DS*
Active to Data Valid
Hold Time from either RD*, WR*,
or DS* Inactive to CS* Inactive
Hold Time from CS* Inactive to
Data Bus 3–state
Wait Time from either WR* or DS*
Active to Latch Data
Data Set Up Time to either WR* or
DS* Inactive
Data Hold Time from either WR* or
DS* Inactive
Address Hold from either WR* or
DS* inactive
(0° ° ° ° C to 70° ° ° ° C; V
0° ° ° ° C to 70° ° ° ° C; V
-40° ° ° ° C to +85° ° ° ° C; V
-40° ° ° ° C to +85° ° ° ° C; V
SYMBOL
MIN
t1
0
t2
0
t3
t4
0
t5
5
t6
75
t7
10
t8
10
t9
10
107 of 117
= 3.3V ± ± ± ± 5% for DS21354L;
DD
= 5.0V ± ± ± ± 5% for DS21554L;
DD
= 3.3V ± ± ± ± 5% for DS21354LN;
DD
= 5.0V ± ± ± ± 5% for DS21554LN)
DD
TYP
MAX
UNITS
75
20
DS21354 & DS21554
NOTES
ns
ns
ns
ns
ns
ns
ns
ns
ns

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds21354lnDs21554lDs21554ln

Table of Contents