GBF Ventless Electric Fryer
GBF-35D & 50D-VH
6.01
Boil-Out Procedure - Cleaning the Fry Vat -continued
NEVER drain boil-out solution into the Filter Pan or run it through the filter system with
Filter Pump. The solution is caustic and will damage the pump and other components,
which is not covered by the factory warranty!
12. Disconnect Filter Pan hose and remove the Filter Pan from the
unit.
13. Position a suitable heat-resistant container
with Fryer) beneath the Fryer drain. Common plastic containers
are generally not acceptable for draining hot boil-out solution
into, as they crack or melt. Metal containers are best.
14. Slowly move the Drain Valve Handle
15. As vat drains, use the provided heat-resistant brushes to
scrub sides, bottom, and heating elements to remove
residue. Rinse and flush the vat thoroughly with warm
clean tap water. Take care not to damage the
temperature probes protruding through the front wall
of the vat.
Be sure to give ample attention to the catch container while draining and rinsing the vat.
Empty it as often as needed to avoid overflow.
78
(not supplied
to the [OPEN] position.
6
5
NOT THE
FILTER PAN
Temperature probes.