Commissioning Guidance For Single-Vfd Integrated Machine - INVT Goodrive300-01A Series Operation Manual

Vfd for air compressor
Hide thumbs Also See for Goodrive300-01A Series:
Table of Contents

Advertisement

Goodrive300-01A series VFD for air compressor

4.3 Commissioning guidance for single-VFD integrated machine

4.3.1 Wiring diagram for single-VFD integrated machine
Emergency stop
Auxiliary temperature
Oil gas temperature
Discharge pressure
Auxiliary pressure
Figure 4-18 Wiring diagram for single-VFD integrated machine system
Note:
1.
RO1 port of single-VFD integrated machine is connected to solenoid valve coil port by default
before delivery. If the touch screen used are made by other manufactures other than INVT,
please set RO1 to solenoid valve control (P06.03=28).
2.
Refer to 4.2.2 Commissioning guidance for single-VFD air compressor for the commissioning
guidance of single-VFD integrated machine.
S1
S3
S4
S5
COM
COM
COM
S2
PTA1
PT100
PTB1
PTA2
PT100
PTB2
P1+
P1-
P2+
P2-
U2 V2 W2
M
Cooling fan
R S T PE
R S T
GD300-01A VFD
integrated machine
7.5-11kW
RO1
0V
0V/TC
110V
110V/TAL
220V
220V/TAH
R
S
CN11
CGND/PE
CN10
U1 V1 W1
M
Main motor
-27-
Commissioning instruction
Solenoid coil
Wireless data
collection terminal
485+
485-
+24V
GND
485+
485-
+24V
GND
HMI
485+
485-
+24V
Power
GND
detection
485+
485-
module

Advertisement