The fan must be cleaned with the fire out, the appliance
completely cold and with the power cable disconnect-
ed.
The extractor fan is only to be cleaned by a T.A.C. (Tech-
■ ■
nical Assistance Centre) or qualified technician.

10.12 CLEANING THE ROOM FAN

Any dust or ash deposits on the extractor fan blades may result
in the fans becoming noisy when the appliance is in operation. It
must be cleaned.
It is recommended that any deposits which may have formed in
the hot air outlet grilles are also removed.
i
Use a vacuum cleaner or compressed air cleaner for
this.
Recommended cleaning frequency: refer to the section
■ ■
" SCHEDULED MAINTENANCE ".
a
The fan must be cleaned with the fire out, the appliance
completely cold and with the power cable disconnect-
ed.
The extractor fan is only to be cleaned by a T.A.C. (Tech-
■ ■
nical Assistance Centre) or qualified technician.
To access the room fan/s (1):
- remove the side panel/s
- it is recommended that a vacuum cleaner and a soft brush is
used. Make sure the internal fan does not get damaged
- refit the side panel/s.
1
Fig. 61
DT2003165_H072218EN0_00
PRODUCT INFORMATION, INSTALLATION AND MAINTENANCE

10.13 CLEANING THE SMOKE OUTLET

Soot and Flyash: formation and need for removal.
The products of combustion will contain small particles of flyash.
The flyash will collect in the exhaust venting system and restrict
the flow of the flue gases.
Incomplete combustion, such as occurs during startup, shut-
down, or incorrect operation of the room heater will lead to some
soot formation which will collect in the exhaust venting system.
The exhaust venting system should be inspected at least once
every two months during the heating season to determine if
cleaning is necessary.
The frequency with which the smoke outlet is to be cleaned de-
pends on the how much the appliance gathers dirt.
i
Recommended cleaning frequency: refer to the section
" SCHEDULED MAINTENANCE ".
Please refer to and carefully read the section " FLUE
■ ■
PIPE ".
a
If necessary, particularly on the first few occasions, we
recommend calling a qualified technician.
Smoke outlet 2
Refer to the section " CONNECTION TO THE SMOKE OUTLET ".
Proceed as follows:
- remove the side panel (A)
- remove the plug (B) by loosening the screws (C)
- clean the flue pipe.
A
C
B
Fig. 62