PRODUCT INFORMATION, INSTALLATION AND MAINTENANCE
- Chimney must meet requirements of CAN/ULC-S629, Standard
for 650°C Factory Built Chimneys.
- Follow Manufacturer's guidelines concerning height and clear-
ances to combustibles.
- Use the same manufacturer's components to provide an effec-
tive vapor barrier where the chimney or other component pen-
etrates to the exterior of the mobile home.
- DO NOT MIX COMPONENTS FROM DIFFERENT MANUFAC-
TURERS.
- The top section of chimney and the chimney cap must be re-
movable to a maximum height of 13-1/2' for transport of the
mobile home.
- Floor protection and clearances requirement must be followed
precisely as shown in the previous paragraphs.
PL Vent must be used for exhaust venting (single wall vent is not
allowed). Follow PL Vent manufacturer's installation directions
and observe all listed clearances to combustibles.
Check any other local buildings codes or other codes that may
apply.
FLOOR
PROTECTION
FLOOR
METAL CHASSIS
d
WARNING: DO NOT INSTALL IN A SLEEPING ROOM.
a
Combustion air must come from the outside of the mo-
bile home.
Failure to do so may create negative pressure within
■ ■
the mobile home and could disrupt proper venting and
operation of the pellet stove.
The user must routinely inspect the point where air is
■ ■
drawn in to insure that it is clear of leaves/debris and
ice or snow.
22
a
a
■ ■
A
B
Fig. 23
DT2003165_H072218EN0_00
CAUTION: THE STRUCTURAL INTEGRITY OF THE
FLOORS, WALLS, CEILING AND ROOF MUST BE MAIN-
TAINED.
The stove is hot while running. Keep children, clothing
and furniture away. Contact may cause skin burns.
Keep combustible materials such as grass, leaves,etc. at
least 4 ft (1,2 m) away from the point directly under the
vent termination.