2.8

TECHNICAL DATA

Description
Power Setting
Fuel
Heat Input
Heat Output
Hourly fuel consumption
Burn Rate (dry)
Heating Efficiency (LHV basis)
Heating Efficiency (HHV basis)
CONTENT OF SMOKE EMISSIONS
Overall Particulate Emission Rate
CO emissions
ELECTRICAL DATA
Current during ignition phase
Electrical power input during ignition phase
Current in operation
Electrical power input in operation
Rated Voltage
Rated Frequency
PHYSICAL DATA
Approximate hopper capacity
Vent size
Weight of appliance with cladding
AIR FLOW
Fresh air intake size (internal diameter)
CERTIFICATION DATA
Evaluation center (Laboratoty)
Test report
UT0014
U.S. ENVIRONMENTAL PROTECTION AGENCY Certified to comply with 2020 particulate emission standards using pellet fuel.
Laboratory data, in accordance with the product technical regulations.
The above data vary in relation to the size and type of fuel used (refer to the section " FUEL "), chimney vacuum and system characteristics.
Data regarding the electric power input vary depending on the network voltage.
PRODUCT INFORMATION, INSTALLATION AND MAINTENANCE
Model
Unit of meas-
High burn rate
urement
Btu/hr
37258
KJ/hr
39277
kW
11.50
Btu/hr
30927
KJ/hr
32600
kW
lb/hr
kg/hr
lb/hr
kg/hr
%
%
g/hr
g/hr
A
W
A
W
V
Hz
lb (kg)
gal (l)
in (mm)
lb (kg)
in
mm
COD_ETICH
DATA_REV
DT2003165_H072218EN0_00
LIA
Medium burn
Low burn rate
rate
P4
P2
natural pure wood pellets
17383
18325
5.08
14568
15358
9.05
4.26
4.61
2.15
2.09
0.98
4.35
2.03
1.97
0.92
89.4
90.3
83.0
83.8
0.700
1.13
0.0
3.07
372
1.39
1.25
97
82
120
60
37.5 (17)
7 (27)
3 (75)
276 (125)
2
51
Intertek Testing Services NA Inc.
102598298MID-006
IND_ETICH
IND_ETICH
REV_ETICH
REV_ETICH
Overall burn
rate
P1
10827
17417
11413
18361
3.17
5.09
8996
14628
9483
15420
2.63
4.28
1.34
2.15
0.61
0.97
1.26
2.03
0.57
0.92
89.5
90.5
83.1
84.0
3.30
1.83
1.2
-
74
-
IND_ETICH
REV_ETICH