Use; Humidifier (Accessories); Cleaning And Maintenance - Piazzetta LIA Product Information, Installation And Maintenance

Table of Contents

Advertisement

PRODUCT INFORMATION, INSTALLATION AND MAINTENANCE
Majolica panel
- Position the tiled panel (1) in the relevant slots (2)
- make sure that the top surface panel is level and if necessary
shim the parts which rest on the fibreglass tape provided
- position the hole covers (3).
2
9

USE

i
For information regarding operation, please refer to
the manual " OPERATING INSTRUCTIONS ".
9.1

HUMIDIFIER (ACCESSORIES)

The appliance is equipped with a system to humidify the environ-
ment (accessories).
i
The humidifier is to be filled with water on average
every two or three days and in any case, on the basis of
appliance use.
a
Do not fill the humidifier beyond the level marked
"MAX". If any water were to leak out, it could damage
the appliance.
Refilling operations are to be carried out with the fire
■ ■
out and when the appliance has cooled down com-
pletely.
The humidifier is to be cleaned with the fire out, with
■ ■
the appliance off and disconnected from the electrical
power source.
32
3
1
3
2
Fig. 51
DT2003165_H072218EN0_00

10 CLEANING AND MAINTENANCE

a
For all installation and maintenance interventions
which require access to inside the cladding, the smoke
chamber or access to electrical and electronic parts, the
user must contact a T.A.C. (Technical Assistance Centre)
or qualified technician.
All installation, cleaning and maintenance work is to be
■ ■
carried out when the fire is out, the appliance is cold
and with the power cable of the product itself and/or
any other accessories disconnected.
This work must also be carried out using suitable equip-
■ ■
ment and in full compliance with all health and safety
regulations.
a
After installation, cleaning and maintenance work:
restore and replace all worn or damaged parts with
■ ■
original spare parts
restore all initial connections together with the normal
■ ■
operating conditions of the appliance and the system
carry out a start-up and operating test to check that
■ ■
there are no faults.
Maintenance interventions are mandatory in order to ensure
safety, for correct and efficient stove operation and to guarantee
a long life of operation. If maintenance is not carried out with the
recommended frequency, appliance performance could suffer
and/or malfunctions could occur.
The manufacturer will not be responsible for appliance dete-
rioration or malfunction if due to poor maintenance.