When chimneys are relined, a chimney chase cap that reduces the
outlet of the chimney to the size of the liner is required. Extend
the exhaust vent above the chimney chase cap and finish it off
with a rain cap.
A single wall liner may need to be insulated to maintain ade-
quate exhaust temperatures in the vent system.
a
Outside Chimneys frequently are difficult to keep
warm: it is recommended that you insulate the liner.
Venting into the side of an existing masonry chimney must be
done through a masonry thimble. When wall penetration is nec-
essary to access a masonry chimney, use a listed PL vent wall
thimble.
When venting into a Class A steel chimney, use an appropriate PL
Vent adapter.
SEE VENT
MANUFACTURER'S
INSTRUCTIONS
PL VENT ADAPTER
a
Strictly observe the PL Vent manufacturer's safety spec-
ifications.
INSTALL EXHAUST VENT AT CLEARANCES SPECIFIED BY
■ ■
THE MANUFACTURER.
Ensure that all installation work is carried out to profes-
■ ■
sional standards.
18
4.7
INSTALLING INTO AN EXISTING FIREPLACE
CHIMNEY
This kind of installation also provides natural draft in the event of
a power failure.
When installing as a hearth mount stove into a firebox the unit
must either be relined, terminating above the chimney chase top,
or positively connected to the existing chimney system using a
block off plate.
An approved flex liner of PL vent must be used.
VENT
TEE
In some areas it is required that the vent pipe extend all the way
FRESH AIR
to the top of the chimney. The pipe or liner inside the chimney
INTAKE
should be 4" (10 cm) diameter.
Fig. 15
DT2033038-1
DT2003165_H072218EN0_00
POSITIVE
BLOCK OFF PLATE
TEE
DT2033039-0
Fig. 16
RAIN CAP
CHIMNEY FLASHING
PL VENT SYSTEM
POSITIVE
BLOCK OFF PLATE
TEE
DT2033040-0
Fig. 17