a
Any stove installed in a mobile home must be electrical-
ly grounded to the steel chassis of the home and bolted
to the floor in Model compliance with, and according to
building code requirements.
a
Ensure that the electrical plug is accessible also after
installation of the stove.
In Canada, the electrical installation must meet the ap-
■ ■
pliance requirements for CSA C22.2
6.6.2 Room temperature probe
Connect the room temperature probe provided to the designat-
ed connector on the appliance The bulb of the probe must be in
a position which allows the most accurate reading of the room
temperature to be taken.
i
If the probe is not connected, an acoustic signal is giv-
en (refer to the manual " OPERATING INSTRUCTIONS "
in the section " MESSAGES - ALARMS - ANOMALIES ").
6.6.3 External environment thermostat
The appliance allows for connection to an external thermostat
(not supplied as standard). This allows operation to be deter-
mined on the basis of the room temperature detected by the
thermostat.
For installation:
- disconnect the appliance from the electrical power supply
- remove the right panel
- refit the board protection
- arrange a 2x20 AVG cable (2) and connect it to one side of the
room thermostat (1)
- remove the knockout (3) on the back panel
- insert the thermostat cable into the PG7 cable gland and then
insert it into the prearranged hole
- connect the cable to the 2 PIN terminal (5) supplied
- insert the terminal (5) into its own seat on the board (4).
4
5
3
1
2
30
a
Consent must arrive from a non-powered contact (nor-
mally open). Do not connect any live elements.
i
For information regarding operation, please refer to
the manual " INFORMATION REGARDING OPERATION "
in the section " EXTERNAL THERMOSTAT ".
6.7

N.PEL CONTACT

The N.PEL connection is used to connect up an external safety
device that may be required by local law.
This stops the appliance from functioning in case of a fault.
For installation:
- the appliance must not be connected to the electrical power
supply
- arrange a 2x0.5 mm
- connect the cable to the external device and to a 2-pin terminal
(2) (not provided as standard)
- access the electronic control unit (3)
- insert the terminal (4) in the relevant attachment on the board
i
Only connect devices approved by Gruppo Piazzetta
S.r.l.. For more information on installation and opera-
tion, please contact a T.A.C. (Technical Assistance Cen-
tre) or qualified technician.
a
Consent must arrive from a non-powered contact (nor-
mally open). Do not connect any live elements.
i
Use a 2x0.5 mm
plicazione!.
Fig. 46
DT2003165_H072218EN0_00
cable (1)
2
4
3
2
2
cable to make the connection !da du-
1
DT2035104-0